MAT GRADES — 105 VERIFIED MATERIALS • 100% ITEM-LEVEL PROVENANCE

Material Comparison Engine

Compare verified materials with source-specific conditions, units, and property limits.

Material A (Baseline)
Material B (Comparison)
1. Identity, Classification & Standards
Parameter6061 Aluminum7075 Aluminum
Material FamilyAluminum & Aluminum AlloysAluminum & Aluminum Alloys
SubfamilyWrought Aluminum AlloysWrought Aluminum Alloys
AA Designation60617075
UNS DesignationA96061A97075
ISO DesignationAlMg1SiCuAlZn5.5MgCu
2. Chemical Composition Limits (wt %)Source-specific limits and typical values
Element6061 Aluminum7075 Aluminum
Si (Silicon)0.4 – 0.8%≤ 0.4%
Fe (Iron)≤ 0.7%≤ 0.5%
Cu (Copper)0.15 – 0.4%1.2 – 2%
Mn (Manganese)≤ 0.15%≤ 0.3%
Mg (Magnesium)0.8 – 1.2%2.1 – 2.9%
Cr (Chromium)0.04 – 0.35%0.18 – 0.28%
Zn (Zinc)≤ 0.25%5.1 – 6.1%
Ti (Titanium)≤ 0.15%≤ 0.2%
OE (Other Elements Each)OE: ≤ 0.05% eachOE: ≤ 0.05% each
OT (Other Elements Total)≤ 0.15%≤ 0.15%
Al (Aluminum)
3. Physical Properties
Property6061 Aluminum7075 Aluminum
Density · TYPICALUnit: g/cm³2.7 g/cm³2.8 g/cm³
4. Contextual Mechanical PropertiesUnit: SI
Mechanical Parameter6061 AluminumO7075 AluminumO
Modulus of Elasticity · TYPICALUnit: GPa69 GPa72 GPa
Ultimate Tensile Strength · Cold Finished Rod & Bar · O Temper · TYPICALUnit: MPa124 MPa228 MPa
Yield Strength (0.2% Offset) · Cold Finished Rod & Bar · O Temper · TYPICALUnit: MPa55 MPa103 MPa
Elongation (4D) · Cold Finished Rod & Bar · O Temper · TYPICALUnit: %25 %17 %
Shear Strength · Cold Finished Rod & Bar · O Temper · TYPICALUnit: MPa83 MPa152 MPa
Fatigue Endurance Limit (5x10^8 cycles) · Cold Finished Rod & Bar · O Temper · TYPICALUnit: MPa62 MPa117 MPa
5. Electrical & Thermal Conductive Properties
Property6061 Aluminum7075 Aluminum
Electrical Conductivity · O Temper · TYPICALCategory: ELECTRICAL • Unit: % IACS47 % IACS45 % IACS
Coefficient of Thermal Expansion · TYPICALCategory: THERMAL • Unit: µm/(m·K)23.6 µm/(m·K)23.4 µm/(m·K)
Solidus Temperature · TYPICALCategory: THERMAL • Unit: °C582 °C532 °C
Liquidus Temperature · TYPICALCategory: THERMAL • Unit: °C652 °C635 °C
Thermal Conductivity · O Temper · TYPICALCategory: THERMAL • Unit: W/(m·K)180 W/(m·K)173 W/(m·K)
6. Hardness Evaluation (Discrete Scales Preserved)No cross-scale mathematical conversion
Hardness Scale6061 Aluminum7075 Aluminum
HB Hardness · Cold Finished Rod & Bar · O Temper · TYPICAL30 HB60 HB